Mr. Rundell has a rare combination of experimental and computational modeling experience. He has spent an extensive amount of time at Michigan State’s Orthopaedic Biomechanics Laboratories performing injurious impact testing on soft tissues. Mr. Rundell uses this knowledge to determine the mechanisms of injuries resulting from various types of accidents.
Additionally, he has thorough knowledge of state-of-the art computer modeling techniques. Mr. Rundell uses his computational skills at Exponent to generate finite element models often intended to supplement FDA applications for novel medical devices. He has experience generating these types of models for a wide variety of orthopaedic implants. Specifically, he has developed a working computer model of the entire lumbar spine, which is currently being used to evaluate the effect of total disc replacement surgery on spinal biomechanics.
Mr. Rundell is currently completing a Ph.D. in Biomedical Engineering at Drexel University.

Ong KL, Rundell S, Liepins I, Laurent R, Markel D, Kurtz S. Biomechanical modeling of acetabular component polyethylene stresses, fracture risk, and wear rate during press-fit implantation. J Orthop Res 2009; 27(11):1467–1472.
Rundell SA, Guerin HL, Auerbach JD, Kurtz SM. Effect of nucleus replacement device properties on lumbar spine mechanics. Spine 2009; 34(19):2022–2032.
Rundell SA, Auerbach JD, Balderston RA, Kurtz SM. Total disc replacement positioning affects facet contact forces and vertebral body strains. Spine 2008; 33(23):2510–2517.
Baars DC, Rundell SA, Haut RC. Treatment with non-ionic surfactant poloxamer P188 reduces tunnel positive cells in bovine chondral explants exposed to injurious unconfined compression. Biomech Model Mechanobiol 2006; 5(2–3):133–139.
Jex CT, Wan CJ, Rundell S, Haut RC, MacDonald B, Wertheimer SJ. Analysis of three types of fixation of the Weil osteotomy. Foot Ankle Surgery 2006; 45(1):13–19, 2006.
Rundell SA, Haut RC. Exposure to a standard culture medium alters the response of cartilage explants to injurious unconfined compression. J Biomech 2005; 26, July.
Rundell SA, Baars DC, Phillips DM, Haut RC. The limitation of acute necrosis in retro-patellar cartilage after a severe blunt impact to the in vivo rabbit patello-femoral joint. J Orthopaedic Res 2005; 23(6):1363–1369.
Rundell SA. Investigation of the acute injury response of articular cartilage in vitro and in vivo: Analysis of various therapeutic treatments. M.S. Thesis, Michigan State University, 2005.
Presentations and Published Abstracts
Rundell SA, Isaza J, Guillory S, Day JS, Kurtz SM. Posterior muscle activation in the lumbar spine engages facet contact and reduces shear forces in the intervertebral disc during simulated standing. Poster Presentation, 56th Annual Meeting of the Orthopaedic Research Society, 2010.
Rundell SA, Isaza J, Guillory S, Day JS, Kurtz SM. The role of facet contact in reducing intervertebral shear during simulated standing. Oral Poster Presentation, 10th Annual Meeting of the Spinal Arthroplasty Society, 2010.
Rundell SA, Siskey R, Isaza J, Kurtz SM. Disc height distraction increases range of motion and impingement risk in fixed and mobile bearing total disc replacements. Oral Poster Presentation, 10th Annual Meeting of the Spinal Arthroplasty Society, 2010.
Rundell SA, Guerin HL, Yim J. The Development of a model for use in evaluating degenerative disc disease. Poster Presentation, 10th Annual Meeting of the Spinal Arthroplasty Society, 2010.
Angibaud LD, Steffens J, Rundell SA, Hayes A, Weisenburger JN, Haider H. Effects of tibial insert slope on polyethylene wear and stress. 54th Annual Meeting of the Orthopaedic Research Society, 2008.Rundell SA, Guerin HL, Auerbach JD, Kurtz SM. Nucleus pulposus replacement material stiffness properties affect vertebral body strains and remodeling response. Podium Presentation, 8th Annual Meeting of the Spine Arthroplasty Society, 2008.
Rundell SA, Auerbach JD, Balderston RA, Kurtz SM. Evaluation of the influence of TDR positioning on subsidence and facet arthrosis. Podium Presentation, 8th Annual Meeting of the Spine Arthroplasty Society, 2008.
Yim J, Bowman B, Paganelli J, Rundell S, Jahng T, Watson R. A finite element analysis to predict peak bending and shear stresses on the Nflex dynamic stabilization device and comparison to empirically derived fatigue data. Poster Presentation, 8th Annual Meeting of the Spine Arthroplasty Society, 2008.
Rundell S, Gimbel J. Evaluation of pedicle screw loosening in a combined facet and total disc replacement system. Poster Presentation, 8th Annual Meeting of the Spine Arthroplasty Society, 2008.
Rundell SA, Auerbach JD, Balderston RA, Kurtz SM. Effects of TDR implantation and positioning on adjacent level facet forces and disc pressures. Poster Presentation, 8th Annual Meeting of the Spine Arthroplasty Society, 2008.
Coleman JC, Bowden A, Rundell S, Nockels RP, Foley KT. Effect of semi-rigid posterior rods on kinematic stability and load distribution in the lumbar spine. Poster Presentation, Congress of Neurological Surgeons, 2008.
Ong K, Rundell S, Liepins I, Laurent R, Markel D, Kurtz S. Biomechanical evaluation of acetabular component polyethylene stresses, fracture risk, and wear rate during press-fit implantation. Poster No. P10, 2nd Joint Meeting of the Bone Research Society and the British Orthopaedic Research Society, Manchester, UK, June 23–25, 2008.
Ong K, Rundell S, Markel D, Kurtz S. Biomechanical evaluation of acetabular component polyethylene stresses, fracture risk, and wear rate during press-fit implantation. Poster P22, 20th Annual Symposium of the International Society for Technology in Arthroplasty, Paris, October 4–6, 2007.
Rundell SA, Auerbach JD, Balderston RA, Kurtz SM. Total disc replacement positioning affects facet contact forces and vertebral body strains. Poster Presentation 54th Annual Meeting of the Orthopaedic Research Society, 2008.
Ong K, Rundell SA, Markel D, Kurtz SM. Biomechanical evaluation of acetabular component polyethylene stresses, fracture risk, and wear rate during press-fit implantation. 54th Annual Meeting of the Orthopaedic Research Society, 2008.
Baars DC, Rundell SA, Haut RC. Acute repair of chondrocyte membranes can help prevent DNA fragmentation. 52nd Annual Meeting of the Orthopaedic Research Society, 2006.
Rundell SA, Haut RC. Tissue equilibration alters the response of cartilage explants to unconfined compression. 51st Annual Meeting of the Orthopaedic Research Society, 2005.
Rundell SA, McPhilamy A, Orth M, Haut RC. Glucosamine supplementation can help limit matrix damage and adjacent cell death in traumatized explants. 51st Annual Meeting of the Orthopaedic Research Society, 2005.